Projects

CLIENT

Cooper Energy Services

SCOPE OF WORK

Design, supply, and erection of four off-skid acoustic Enclosures and exhaust systems for compressor buildings. The enclosures were supplied with acoustic ventilation systems complete with fans, ventilation intake and exhaust silencers, and lube oil silencer. INNOVA’s acoustic equipment doors were utilized in conjunction with an innovative crane system designed for removal of the turbine or compressor for maintenance.

INNOVA also supplied auxiliary fire suppression, fire and gas detection, electrical systems, gas turbine exhaust systems and utility buildings at each station.

ACOUSTICAL REQUIREMENTS

Acoustic requirement varied from 40 - 51 dBA at 100 m

NOISE SOURCES

Rolls-Royce RB211 DLE Turbo-compressor packages

Original source noise levels: 120 dBA

RESULTS

INNOVA met all acoustical requirements using their Type E and Type J walls inside the compressor buildings.