Projects

CLIENT

TransCanada Energy Ltd.

PROJECT DESCRIPTION

Acoustic Buildings were designed, supplied and installed at the following sites:

  • Cabri, Saskatchewan
  • Herbert, Saskatchewan
  • Caron, Saskatchewan
  • Grenfell, Saskatchewan
  • (2) Ile des Chenes, Manitoba
  • Vermillion Bay, Ontario
  • Martin, Ontario
  • Nipigon, Ontario
  • Calstock, Ontario
  • Potter, Ontario
  • Bracebridge, Ontario
  • Lincoln, Ontario

SCOPE OF WORK

Design, supply, and installation of acoustic compressor control buildings at 13 sites in Saskatchewan, Manitoba, and Ontario. 

ACOUSTICAL REQUIREMENTS

Acoustical requirements varied for each site- 39 dBA - 45 dBA at 100 m from the buildings.

NOISE SOURCES

Cooper turbo compressor package based on:

  • Rolls-Royce RB211 gas turbine
  • Siemens 28.3 MW synchronous motor

Source noise levels expected: 110 dBA - 140 dBA