Projects

CLIENT

Finning Power Systems Ltd.

SCOPE OF WORK

INNOVA designed, supplied and installed three (3) on-skid acoustic enclosures for auxiliary power units, complete with acoustic ventilation systems and fans. The units were assembled and pre-tested for acoustic and generating performance at the client’s premises, which resulted in cost savings to the client. The units could then be easily transported to the desired location for installation and commissioning. 

ACOUSTICAL REQUIREMENTS

  • 42 dBA at 100 meters from building
  • Original source noise levels: 100 dBA

NOISE SOURCES

 Three (3) Caterpillar G3408TA / 270 KW Engines / Gensets

RESULTS

INNOVA designed the acoustic enclosures to achieve an STC 41 rating, and all acoustical requirements were met.